In the hybrid-core version of the exposed fixing wall panel, the core is rock wool based with polyurethane strips along the edges. The strip holds the screw seating tightly; this works directly in an exposed fixing system where the screw passes through the face.
Fire class A2-s1-d0, thermal conductivity 0.045 W/mK. Thickness goes up to 200 mm.
It is chosen for facilities on open terrain with high wind suction and for façades where class A2 is mandatory. Fastener selection and installation notes are in the Library section.