The EPS-cored version of the exposed fixing wall panel is the most economical option in the range. The profile is micro-ribbed and the panel is produced in single lengths of up to 15.5 metres.

The thermal conductivity of the EPS core is 0.038 W/mK, which means the same insulation value requires more than twice the thickness of a polyurethane-cored panel. In heated or cooled spaces this difference cannot be closed; the panel suits buildings where the insulation requirement is limited.

There is no published EN 13501 fire class for this product and the class field has been left blank. In a project where fire performance is decisive, an EPS-cored panel is not considered; the rock wool or PUR-PIR cored version is used instead.